Generic Diagnostic Plots for 13MHz CDDO SeaSonde Site for the time period of Feb./08/09 – June/07/09
Posted on June 12th, 2009 No commentsAll of the plots below are from the diagnostic files obtain from CDDO for the time period of 02/08/2009 to 06/07/2009. All plots have 4 subplots that represent different time spans. In all of them there seems to a problem with the CDDO radar from March 14-17 and April 3. The gap in all plots from March 14-17 was due to a power supply problem. The CDDO radar did not had any electrical power supplied to it because the transformer that supplied energy to the system caught fire. Except for this time periods the CDDO radar seems to be working well with expected values in all of the plots. To obtain more information about any individual plot click on it.
Last 5 posts by admin
- Quality Control of Bistatic Signals - June 7th, 2012
- Radial Coverage for March 2012 - April 23rd, 2012
- ru23 as a drifter, Travis Analysis - February 14th, 2012
- Fisher Island - Ideal Pattern Results - February 2nd, 2012
- Yorktown Express - January 31st, 2012