Outage Information
2026-08-03 04:00:05
Opened Outage Report
Teresa Updyke

2026-08-03 04:00:05
equipment overheating, transmit turned off
Teresa Updyke

2026-08-03 03:00:00
Status switched to 'In Progress'
Teresa Updyke

2026-08-11 12:19:50.226000
Outage cleared automatically. Radial files have caught up since initial reporting.
Automated Bot

2026-08-14 21:03:15.839000
2026-07-30 21:18:27 GMT rwsadmin (TGU) Installed qccodar 2.1.0 This version can use additional QC available in SeaSonde Radial Suite R25
Automated Bot

2026-08-14 21:03:15.839000
2026-08-07 12:50:47 GMT rwsadmin (TGU) sheet of ice on the air conditioner condensor and fan inside cabinet is not spinning
Automated Bot

2026-08-14 21:03:15.840000
2026-08-07 14:11:34 GMT rwsadmin (TGU) removed HVAC for repair, installed the air conditioner that was at CEDR (verified that this one worked, checked out by Professional Heating and Cooling HVAC tech at ODU)
Automated Bot

2026-08-14 21:03:15.840000
2026-08-07 15:00:08 GMT rwsadmin (TGU) Replaced Suncourt 6-inch duct fan model DB206C
Automated Bot

2026-08-14 21:03:15.840000
2026-08-07 15:00:28 GMT rwsadmin (TGU) Swapped out disk drive, checked antennas