Automatic Outage: Radials older than 12 hours. Operator should investigate.
Outage cleared automatically. Radial files have caught up since initial reporting.
Status switched to 'Closed'
2026-07-21 18:18:53 GMT codar visited site and turned computer back on. Handel
2026-07-23 17:12:23 GMT codar visited site and turned computer back ON, Handel
2026-07-28 17:36:00 GMT codar Changed settings in LLUVQuality.plist; Increased Neighborhood Bearing Coverage for Lonely Vector from 10º to 11º, Decreased Neighborhood Bearing Coverage for Radial Outliers Velocities from 12º to 11º, Decreased Neighborhood Bearing Coverage for Interpolative Fill from 20º to 11º, Decreased Neighborhood Range Multiplier for Interpolative Fill from 3 to 1.5, and Increased Threshold Minimum Neighbors for Interpolative Fill from 3 to 4. Handel
2026-07-29 16:50:16 GMT codar visited site and installed CyberPower 1500VA (1000W) UPS. Plugged UPS into HomeDepot multi-outlet extension cord and plugged WebPowerSwitch into UPS. Also connected UPS to computer via USB cable to enabled CyberPower Power Panel software on computer to communicate with UPS. Handel