Automatic Outage: Radials older than 12 hours. Operator should investigate.
Outage cleared automatically. Radial files have caught up since initial reporting.
Outage closed automatically after 14 days in Resolved status.
2026-07-10 15:08:35 GMT codar Visited site to recover SSD. Computer was off again this morning after power outage last night. David Cassidy turned it back on this morning, but computer would not fully boot up until SSD was unplugged. Handel
2026-07-14 16:07:05 GMT codarprocessed and installed new AISAPM using 21° smoothing and 1wk loops due to a step change in forward power on July 6th. Reprocessing eligible from July 6th till now. Set phases to -170, -171 per phases.txt Stolarz
2026-07-20 16:14:55 GMT codar Had David Cassidy turn computer back on. Computer had been off since 7/16 @ 11AM. Handel