Automatic Outage: Radials older than 12 hours. Operator should investigate.
Outage cleared automatically. Radial files have caught up since initial reporting.
Outage closed automatically after 14 days in Resolved status.
2026-06-04 17:44:58 GMT codar switched from 26.3MHz to 24.55MHz for testing to try and improve SNR in cross loops since TR ant#2023362 was tuned for 24.5 and not 26.3. Handel
2026-06-04 19:20:34 GMT codar adjusted phases for ideals to 126 & -123. Handel
2026-06-04 19:28:28 GMT codar changed alignment from 1750 to 2500 for testing. Handel
2026-06-05 14:25:01 GMT codar increased # of range cells for spectra processing from 50 to 64 and decreased alignment from 2500 to 2000. Handel
2026-06-05 14:40:10 GMT codar changed alignment to 1825. Handel
2026-06-05 15:51:19 GMT codar adjusted FOLS; increased points to smooth doppler bins from 2 to 3, reduced required signal above noise floor from 7 to 6dB, unchecked stop at null, reject Bragg when first order is far from Bragg index, reject Bragg when noise is above Bragg, and checked look for split Bragg 8dB power balance. Handel
2026-06-05 16:18:31 GMT codar processed and installed new PFS APM from past 6 Basic Loops with 10ºsmoothing. Handel
2026-06-08 14:50:13 GMT codar increased range cells for radial processing from 45 to 60. Handel