Outage Information
2026-05-17 01:11:48.475000
Automatic Outage: Radials older than 12 hours. Operator should investigate.
Automated Bot

2026-05-17 13:11:48.475000
Outage cleared automatically. Radial files have caught up since initial reporting.
Automated Bot

2026-05-31 12:11:29.154000
Outage closed automatically after 14 days in Resolved status.
Automated Bot

2026-08-14 21:03:12.666000
2026-05-11 18:30:19 GMT codar adjusted wave settings to use 512 doppler bins from 1024. Also changed wave coastline settings from 20º-110º to 10º-90º, and changed bearing limits from 55º-125º to 20º-85º. Handel
Automated Bot

2026-08-14 21:03:12.666000
2026-05-11 18:48:04 GMT codar processed and installed new AISAPM from last 15 days loops. Handel
Automated Bot

2026-08-14 21:03:12.666000
2026-05-14 14:32:16 GMT SeaSonde Radial Suite R25 Installed
Automated Bot

2026-08-14 21:03:12.666000
2026-05-14 15:07:23 GMT codar installed R25 and enabled Radial Filler and set bearing resolution to 1º. Handel
Automated Bot

2026-08-14 21:03:12.666000
2026-05-14 15:33:38 GMT codar updated AWG firmware from 3.42T to 3.50T. Handel
Automated Bot

2026-08-14 21:03:12.667000
2026-05-15 19:28:27 GMT codar visited site and plugged receiver USB directly into Mac and not the keyboard. AIS and Receiver are still on the same USB bus, but at least they are both on a 3.1 bus and neither is on a 2.1 bus. I tried different combinations of adapters and ports but was unable to get the AIS and Receiver on separate buses. Handel
Automated Bot

2026-08-14 21:03:12.667000
2026-05-16 13:52:03 GMT codar switched radical resolution to 5 degrees. Roarty
Automated Bot

2026-08-14 21:03:12.667000
2026-05-17 12:10:32 GMT codar disabled QC step to make empty radials if vector count falls below 300. Handel
Automated Bot

2026-08-14 21:03:12.667000
2026-05-18 17:24:43 GMT codar pulse shaping off, enhanced blanking enabled to default settings. RUCODAR
Automated Bot

2026-08-14 21:03:12.667000
2026-05-18 18:59:03 GMT codar changed bearing resolution back to 1º for testing. Handel
Automated Bot

2026-08-14 21:03:12.667000
2026-05-19 15:38:31 GMT codar deleted old /Radials/IdealPattern folder and added a symlink to the new /RadialMergers/IdealPattern folder to allow for ideal radial rsync. Stolarz
Automated Bot

2026-08-14 21:03:12.667000
2026-05-19 18:54:48 GMT codar disabled Enhanced Waveform Blanking and reenabled Pulse shaping. Handel
Automated Bot

2026-08-14 21:03:12.667000
2026-05-21 14:03:37 GMT codar changed radial resolution back to 5° until the 25MHz totals issue is resolved. Stolarz
Automated Bot

2026-08-14 21:03:12.667000
2026-05-21 16:31:55 GMT codar reenabled Callsign. Handel
Automated Bot

2026-08-14 21:03:12.667000
2026-05-22 16:04:17 GMT codar visited site due to computer bring OFF and web power switch power cycle did not bring it back ON. Manually pressed power button and computer turned ON. It took a few minutes to boot up, but eventually did and all apps are now running properly. I double checked System Settings and everything appears configured properly, and I ran Disk Utility First Aid on the hard disk but it did not report any issues. Handel
Automated Bot