Automatic Outage: Radials older than 12 hours. Operator should investigate.
Outage cleared automatically. Radial files have caught up since initial reporting.
Outage closed automatically after 14 days in Resolved status.
2026-05-12 19:14:45 GMT SeaSonde Radial Suite R25 Installed
2026-05-12 19:24:01 GMT codar changed bearing resolution from 5º to 1º. Handel
2026-05-12 19:37:30 GMT codar enabled radial interpolative fill option. Handel
2026-05-13 17:45:09 GMT codarvisited site to troubleshoot communications issues. When opening the enclosure, found all equipment except computer were on. Pressed power button on the Mac Mini and it turned on. Had to unplug the external SSD to get it boot past a purple screen. Looked fine. Then the power flickered at the site for a second, and again the computer didnt turn back on. Tried cycling power at the sites WPS manually to the computer and it didnt auto turn back on. Must be some kind of computer issue. Will return with RATHs reconfigured computer. Also moved the AC off the UPS (which is what the WPS is plugged into) and onto the source power multioutlet in the bottom of the enclosure. Stolarz
2026-05-14 15:22:26 GMT codar updated AWG firmware from 3.42J to 4.10J. Handel
2026-05-16 13:49:24 GMT codar switched radial resolution to 5 degrees. Roarty
2026-05-18 14:31:43 GMT codar disabled QC step for making empty radial if vector count was too low. Handel
2026-05-18 18:14:08 GMT codarprocessed and installed new AIS AutoAPM using the pre smoothed file. Set phases to 28, 35 per phases.txt. Handel & Stolarz
2026-05-19 15:31:50 GMT codar deleted old /Radials/IdealPattern folder and added a symlink to the new /RadialMergers/IdealPattern folder to allow for ideal radial rsync. Stolarz