Automatic Outage: Radials older than 12 hours. Operator should investigate.
Outage cleared automatically. Radial files have caught up since initial reporting.
Outage closed automatically after 14 days in Resolved status.
2026-05-11 12:27:57 GMT codar cycled power to receiver. Roarty
2026-05-14 15:36:08 GMT SeaSonde Radial Suite R25 Installed
2026-05-14 16:03:40 GMT codar installed R25 and enabled Radial Filler and set bearing resolution to 1º. Also updated AWG firmware from 3.42T to 3.50T. Handel
2026-05-15 17:49:41 GMT codar visited site and swapped SSD. Also tried to move AIS and SeaSonde Receiver to different USB buses, but I was unable to find any combination of adapters and different ports that could separate them. I was at least able to move the SeaSonde RX to its own port and not be plugged into the keyboard, so at least now both the AIS and SeaSonde are on a USB 3.1 bus and neither on a lower speed 2.0 bus. I also cleaned the AC air filter. The AC shed vent ducts are no longer attached to the AC as mounting plate has come off AC. Handel
2026-05-16 13:50:45 GMT codar switched radial resolution to 5 degrees. Roarty
2026-05-18 18:20:06 GMT codar enabled enhanced blanking for waves and pause shaping is OFF. Handel