Automatic Outage: Radials older than 12 hours. Operator should investigate.
could not connect to the the database for radial QC and totals processing, IT upgraded the database server and the update was incompatible with the HFR Mongo database
Outage cleared automatically. Radial files have caught up since initial reporting.
2026-03-30 18:03:56 GMT codar visited site and removed tx#2011336 due to its small blanking board fan having failed and installed tx#2011335, which is also the matching unit to the existing rx#201335. Handel
2026-03-31 14:53:31 GMT codarprocessed and installed new AISAPM using 6 days loops and 15° smoothing due to drop in coverage from transmitter replacement on 2026-03-25. Transmitter replacement yesterday 2026-03-30 didnt seem to affect the amplitudes or phases drastically. Set phases to -91, -87 per phases.txt. Stolarz
2026-04-07 18:56:47 GMT codar processed and installed new AISAPM from past 13 days loops. Handel