Outage Information
2026-04-02 17:07:14.884000
Automatic Outage: Radials older than 12 hours. Operator should investigate.
Automated Bot

2026-04-02 16:00:00
could not connect to the the database for radial QC and totals processing, IT upgraded the database server and the update was incompatible with the HFR Mongo database
Teresa Updyke

2026-04-02 17:07:25.337000
Outage cleared automatically. Radial files have caught up since initial reporting.
Automated Bot

2026-08-14 21:03:10.040000
2026-04-02 17:07:42 GMT codar visited site and removed transmitter #2011334 due to amplifier fan having failed and installed TX#2011333. Also removed antenna #2011102 due to fluctuating VSWR and intermittent high noise floors and installed antenna #2011103 (taken from RATH). Also set AC to 70ºF from 80ºF. Handel and Stolarz
Automated Bot

2026-08-14 21:03:10.040000
2026-04-03 14:25:14 GMT codar changed phases for ideals from -71 & -91 to -23 & -30, based on past 12 hours of diagnostics. Handel
Automated Bot

2026-08-14 21:03:10.040000
2026-04-03 15:00:57 GMT codar Processed and installed new PFS APM. Coverage very poor. Disabled Measured Radial Generation for now in AnalysisOptions.txt. Handel
Automated Bot

2026-08-14 21:03:10.041000
2026-04-07 15:23:18 GMT codar processed and installed new AISAPM from past 3 days loops with 15ºsmoothing and changed phases for ideals to -19 & -35. Handel
Automated Bot

2026-08-14 21:03:10.041000
2026-04-08 15:10:44 GMT codar processed and installed new AISAPM from last 4 days loops with 20ºsmoothing and edited Angseg. Handel
Automated Bot