Automatic Outage: Radials older than 12 hours. Operator should investigate.
Outage cleared automatically. Radial files have caught up since initial reporting.
Outage closed automatically after 14 days in Resolved status.
2026-02-25 18:38:42 GMT codar visited site due to no comms persisting after blizzard 2 days ago. Found APC UPS reporting its inverter to be in a fault state and not providing power to the web power switch, but I pressed the power button on the UPS and it turned power on to its outlets and the web power switch, and all the equipment plugged into the web power switch powered up normally and appear to be functioning properly. UPS is unable to run a self test, but it appears to be operating fine now. Handel
blizzard, site lost power