Automatic Outage: Radials older than 12 hours. Operator should investigate.
2025-08-25 16:24:31 GMT codar changed the elliptical processing of SPHL to start at RC 6 instead of 4 to crop out large velocity vectors & created and edited angseg for ellipticals to flag out northern vectors which were sparse and reversed. Set bearing limits to 70-160 in elliptical angseg. Handel & Stolarz
2025-08-18 16:49:11 GMT codarprocessed and installed new AIS APM using 15 days loops. Set phases to -166, -104 per phases.txt. Reprocessed some data and there is significant improvement to data distribution to the south and increased centering. Handel & Stolarz
2025-08-22 14:43:11 GMT codar edited AngSeg to flag out the two northernmost and one southernmost vector spokes due to reversed vectors. Handel
Outage cleared automatically. Radial files have caught up since initial reporting