Outage Information
2025-07-14 08:15:12.845000
Automatic Outage: Radials older than 12 hours. Operator should investigate.
Automated Bot

2025-07-17 22:15:29.343000
2025-07-09 14:59:44 GMT codar edited EllipticalOptions.txt to start processing 4 range cells after start verses 3. Handel
Automated Bot

2025-07-17 22:15:29.344000
2025-07-09 15:34:35 GMT codar Created AngSeg_MRHE to flag suspect vectors in eastern edge of coverage. Handle and Stolarz
Automated Bot

2025-07-18 05:15:28.727000
2025-07-17 19:39:09 GMT codar visited site. AC was flooding enclosure with water. The surge strip failed. replaced transmitter. replaced AC. Roarty, Nixon, Defeo MOO
Automated Bot

2025-07-22 05:15:25.888000
2025-07-21 16:42:21 GMT codar increased attenuation to 7dB to lower power out from 122W to 40W; Handel & Roarty
Automated Bot

2025-07-31 20:15:26.431000
Outage cleared automatically. Radial files have caught up since initial reporting
Automated Bot