Outage Information
2025-06-25 08:15:25.035000
Automatic Outage: Radials older than 12 hours. Operator should investigate.
Automated Bot

2025-06-25 17:15:24.525000
2025-06-23 14:01:56 GMT seasonde logged on radial web server during weekly site checks and saw receiver voltage was low again for -5V and +24V power supplies. Cycled power to receiver and now running correctly again. This last happened at this site on 2025-06-10. Stolarz
Automated Bot

2025-06-25 17:15:24.525000
2025-06-24 14:11:33 GMT seasonde cycled power to receiver after seeing its 5v supply had failed again and no transmit signal was being generated. Receiver is now working again. Will visit site and swap receiver. Handel
Automated Bot

2025-06-25 17:15:24.525000
2025-06-24 17:52:23 GMT seasonde visited site and removed receiver #2021620 due to its power supply starting to fail and installed receiver #200033 in its place. Also removed transmitter #2014411 due to it being a tx2 unit and installed transmitter #200150 in its place. Handel
Automated Bot

2025-07-01 05:15:26.984000
2025-06-30 17:34:43 GMT codar disabled emailing script on site due to newer version on file server. Stolarz
Automated Bot

2025-07-01 05:15:26.994000
2025-06-30 17:31:36 GMT seasonde disabled emailing script from site due to newer version on file server. Stolarz
Automated Bot

2025-07-09 15:15:26.308000
Outage cleared automatically. Radial files have caught up since initial reporting
Automated Bot